Comparison of the operating range of a wetted-wall column with a packed column for distillation
- In this paper, a newly designed distillation column consisting of a wetted wall with a rectangular cross section is analyzed and compared with a conventional packed column with regard to the operating range of both apparatuses. As expected, the pressure drop is considerably lower in the wetted-wall column and, therefore, it offers a higher range of operation. However, in the wetted-wall column, the separation efficiency decreases rapidly with increasing F factors. This effect can be overcome by the serial connection of two wetted-wall columns.
Author: | Arnulf ReitzeORCiDGND, Marcus GrünewaldORCiDGND, Julia RieseORCiDGND |
---|---|
URN: | urn:nbn:de:hbz:294-99671 |
DOI: | https://doi.org/10.1002/cite.202000065 |
Parent Title (German): | Chemie Ingenieur Technik |
Publisher: | Wiley-VCH |
Place of publication: | Hoboken, New Jersey |
Document Type: | Article |
Language: | English |
Date of Publication (online): | 2023/06/16 |
Date of first Publication: | 2020/10/12 |
Publishing Institution: | Ruhr-Universität Bochum, Universitätsbibliothek |
Tag: | Fluid dynamics; Pressure drop; Separation efficiency; Small-scale processes; Specialty chemicals |
Volume: | 92 |
Issue: | 12,Special Issue: Flexible Apparate und Prozesse |
First Page: | 1968 |
Last Page: | 1975 |
Note: | Dieser Beitrag ist auf Grund des DEAL-Wiley-Vertrages frei zugänglich. |
Institutes/Facilities: | Lehrstuhl für Fluidverfahrenstechnik |
Dewey Decimal Classification: | Technik, Medizin, angewandte Wissenschaften / Ingenieurwissenschaften, Maschinenbau |
open_access (DINI-Set): | open_access |
faculties: | Fakultät für Maschinenbau |
Licence (English): | Creative Commons - CC BY 4.0 - Attribution 4.0 International |